Metal Honeycomb SCR Catalyst is an SCR catalyst that uses a metal-type supporter. It has a large contact area per unit volume, and can thus minimize the volume of the catalyst. It provides excellent economy, because it is highly durable, has guaranteed long-lasting performance, and can be remanufactured semi-permanently.
Stability
Efficiency
Technological Innovation
Economy
Environmental
Item | Honeycomb | Glass fiber | Plate | Metal Honeycomb |
---|---|---|---|---|
Shape | ||||
Performance | Good | Good | Average | Excellent |
Amount of catalyst | Average | Average | Requires a significantly large amount | Requires a significantly small amount |
Loss from pressure | Average | Average | Low | Low |
Weight | Heavy | Very light | Average | Average |
Thermal response speed | Slow | Ordinary | Average | Fast Note 1 ) |
Durability | Low | Very low | Low | High |
Thermal resistance | Very good | Very poor | Very good | Very good |
Re-manufacturing[recycling] | Once~twice | Not possible | Once~twice | More than 30 times |
Use | Coal thermal · combined heat and power | Coal thermal · combined heat and power | Coal thermal | Coal thermal · combined heat and power · incinerator - ship · refinery & petrochemical plants |
Metal Type | Client | Power plant | Capacity | Completion date | Volume of catalyst | SV | Amount of catalyst | Pressure loss(mmAq) | MOx removal rate |
---|---|---|---|---|---|---|---|---|---|
Metal Foam | GS Power | Bucheon CHP Turbine #1 |
100MW (Exhaust gas 1.2 million m2/hr) | 2017.05 | 16㎥ | SV 75,000hr - 1 (Inlet 60ppm,Outlet 5ppm) | 16㎥ | 100 or lower | 90% or higher |
Metal Honeycomb | GS Power | Bucheon CHP Turbine #3 |
100MW (Exhaust gas 1.2 million m2/hr) | 2019.03 | 16㎥ | SV 75,000hr - 1 (Inlet 50ppm,Outlet 5ppm) | 16㎥ | 50 or lower | 90% or higher |
GS Power | Bucheon CHP Turbine #2 |
100MW (Exhaust gas 880,000 m2/hr) | 2020.05 | 16㎥ | SV 75,000hr - 1 (Inlet 50ppm,Outlet 5ppm) | 16㎥ | 50 or lower | 90% or higher | |
Korea South-East Power | Bundang Combined Thermal Turbines 1 through 5 and 7 |
79,400MW (Exhaust gas 880,000 m2/hr) | 2020.08 | 77㎥ | SV 68,269hr - 1 (Inlet 45ppm,Outlet 5ppm) | 77㎥ | 70 or lower | 90% or higher | |
GS Power | Bucheon CHP Turbine #1 | 100MW (Exhaust gas 1.2 million m2/hr) | 2020.11 | 16㎥ | SV 75,000hr - 1 (Inlet 60ppm,Outlet 5ppm) | 16㎥ | 50 or lower | 90% or higher |